New for 2007, the Kestrel 4200 has made HVAC technicians jobs even easier with automatic humidity ratio readings. Of particular interest to dehumidification professionals, the Kestrel 4200 measures relative humidity and calculates dewpoint, wet bulb temperature and heat stress index as well as the humidity ratio - and the patented dual chamber humidity sensor assures fast and accurate readings in any environment.
Like the 4100, the Kestrel 4200 has taken the calculations and guess-work out of Air Flow measurements with automatic air flow readings. Plus it measures every other environmental parameter and stores over two years worth of information in its built-in data logger. With on-screen customization, the 4200 can truly be personalized for every technician. Easy set-up screens allow unit to display only relevant readings, and hide screens not relative to the job.
Features:
- Barometric Pressure & Trend
- Altitude & Density Altitude
- Relative Humidity & Dew Point
- Wind Chill & Heat Stress Index
- Wet Bulb Temperature
- Current, Average, & Maximum Air Velocity
- Air Flow
- Air Temperature
- Current & Average Wind Speed
- Maximum Wind Gust
- One-button clear and restart of Max Wind Gust and Average Wind measurement`
- Waterproof & Floats
- Manual data capture
- Automatic Data Storage
- Customizable Data Storage - 2000-point data logger with graphical display for each measurement variable
- Auto data storage interval settable from 2 seconds to 12 hours
- Minimum, maximum, average and logged history stored and displayed for every measured value
- Data Upload with optional PC interface and provided software
- Optional RS-232 connection with USB adapter available
- Electroluminescent backlight with automatic or manual activation
- Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment
- User-selectable auto shutdown: 15 or 60 minutes with no keypresses or disabled
- Data Charting
- Five Languages: English, French, Spanish, German, and Italian
- User-replaceable Impeller
- Flip-top Impeller Cover
- Soft Carry Case
- Wrist and Neck Lanyards
- Five-year warranty from the manufacturer
Specifications:
- Wind Speed (sample every 1 second)
- 0.4 to 60 m/s (0.1 resolution, 3% accuracy)
- 59 to 11,948 ft/min (1 resolution, 3% accuracy)
- 1 to 218 km/h (0.1 resolution, 3% accuracy)
- 0.8 to 135 mph (1 resolution, 3% accuracy)
- 0.6 to 118.3 kt (0.1 resolution, 3% accuracy)
- 0 to 12 Beaufort (0.1 resolution, 3% accuracy)
- Air Flow (sample every 1 second)
- 0 to 99,999 cfm (1 resolution, 3% accuracy)
- 0 to 99,999 m3/h (1 resolution, 3% accuracy)
- 0 to 99,999 m3/m (1 resolution, 3% accuracy)
- 0.0 to 9,999.9 m3/s (0.1 resolution, 3% accuracy)
- 0 to 99,999 L/s (1 resolution, 3% accuracy)
- Temperature (sample every 1 second)
- -20.0 to 158.0 °F (0.1 resolution, 1.8 °F accuracy)
- -29.0 to 70.0 °C ( 0.1 resolution, 1.0 °C accuracy)
- Relative Humidity (sample every 1 minute)
- 0.0 to 100.0 % (0.1 resolution, 3.0 %RH accuracy
- Barometric Pressure (sample every 1 second)
- 8.86 to 32.48 inHg
(0.01 resolution, 0.05 inHg accuracy)
- 300 to 1100 hPa / mb
(0.1 resolution, 1.5 hPa / mb accuracy)
- PSI (0.1 resolution)
- Altitude ( sample every 1 second)
- -6000 to 30000 ft (1 res, 50 ft accuracy)
- -2000 to 9000 m (1 res, 15 m accuracy)
- Wind Chill (sample every 1 second)
- -49.0 to 257.0 °F (0.1 resolution, 1.8 °F accuracy)
- -45.0 to 125.0 °C (0.1 resolution, 1.0 °C accuracy)
- Heat Index (sample every 1 minute)
- 0.0 to 100.0 %RH, -49.0 to 257.0 °F
(0.1 resolution, 3.6 °F accuracy)
- -0.0 to 100.0 %RH, -45.0 to 125.0 °C
(0.1 resolution, 2.0 °C accuracy)
- Dew Point (sample every 1 minute)
- 0.0 to 100.0 %RH, -49.0 to 257.0 °F
(0.1 resolution, 3.6 °F accuracy)
- 0.0 to 100.0 %RH, -45.0 to 125.0 °C
(0.1 resolution, 2.0 °C accuracy)
- Wet Bulb (sample every 1 minute)
- -49.0 to 257.0 °F, 0.0 to 100.0 %RH,
8.86 to 32.48 inHg
(0.1 resolution, 3.6 °F accuracy)
- -45.0 to 125.0 °C, 0.0 to 100.0 %RH,
300.0 to 1100.0 hPa
(0.1 resolution, 2.0 °C accuracy)
- Density Altitude ( sample every 1 second)
- FT: -49.0 to 257.0 °F, 0.0 to 100.0 % RH,
8.86 to 32.48 inHg (1 res, 246 accuracy)
- M: -45.0 to 125.0 °C, 0.0 to 100.0 %RH,
300.0 to 1100.0 hPa (1 res, 75 accuracy)
- Power requirements: 2 AAA Alkaline batteries (included)
- Battery life: ±400 hours, depending on backlight use
Dimensions:
- 5.0" x 1.8" x 1.1" (12.7cm x 4.5cm x 2.8cm)
|
|